The Data Logger reads equipment over several physical interfaces and forwards the decoded values to the satlog.io cloud over Iridium. Each message is limited to 100 bytes, so values are sampled and batched at a configurable report interval instead of streamed.

InterfaceConnectorProtocols and equipmentDetails
CAN, 250 kbit/sCAN1 / CAN2, RJ45J1939 engines and generators, NMEA 2000 batteries, AC, engines, tanks, speed and wind, Victron VE.CanCAN bus / NMEA 2000
UART, 19200 8N1VE.Direct, JST PH 4-pinVictron SmartShunt, BMV, MPPT, Phoenix invertersSerial / UART
RS-485CAN1 / CAN2 pins 4 and 5Modbus RTU energy meters and engine controllers, on requestModbus RTU
Bluetooth Low EnergyInternal antennaRuuvi sensors and Gobius tank sensors, passive scanBLE
WiFi access pointInternal antennaStatus page, diagnostics and firmware updateWiFi

Selecting hardware​

  • The Data Logger supports every wired interface above.
  • The Data Logger Wireless is identical in hardware and adds Bluetooth Low Energy scanning.
  • Without a Data Logger, the Modem can be driven by any host that speaks serial at 9600 baud.

Equipment or protocols that are not listed can be supported on request, contact us with your requirements.